Single Loop
Temperature Controllers:

R1100 R1140 R1180 R1300

ON STOCK!

 

R1100 - Bedienungsanleitung

Side up


R1100
Temperature Controller

Manual R1100

Format: 96x96 mm (1/4 DIN)
Installation depth: 67 mm

  • 2-point-controller: (heating or cooling)
  • 3-point-controller: (heating-off-cooling)
  • 3-point-step-controller (for motorvalve application)
  • Continuous-output-controller
  • Autotune function
  • Sensor input: RTD, Thermocouple
  • Alarm outputs with 7 different functions
  • Easy to operate
 

R1140 - Bedienungsanleitung

Side up

 

R1140
Temperature Controller

R1140 - standard
R1140 - standard - Three - Pointstep - controller
R1140 - Profibus DP + CANopen manual
R1140 - Profibus DP- Data-Transfer

Format: 48x96 mm (1/8 DIN)
Installation depth: 122 m

NEW

with Bedienungsanleitung
or with Bedienungsanleitung fieldbus

or with serial interface RS232
(ELOTECH
Standard ASCII - communication protocol )

or with serial interface RS485
(ELOTECH Standard ASCII - communication protocol )


  • 2-point-controller: (heating or cooling)
  • 3-point-controller: (heating-off-cooling)
  • 3-point-step-controller (for motorvalve application)
  • Continuous-output-controller
  • Autotune function
  • Sensor input: RTD,Thermocouple, mA
  • Analogue process value output 0/4 ... 20 mA
  • Second setpoint
  • Alarm outputs with 7 different functions
  • Easy to operate


R1180
Temperature Controller

Manual R1180
Format: 96x48 mm (1/8 DIN)
Installation depth: 122 mm

  • 2-point-controller: (heating or cooling)
  • 3-point-controller: (heating-off-cooling)
  • 3-point-step-controller (for motorvalve application)
  • Continuous-output-controller
  • Autotune function
  • Sensor input: RTD,Thermocouple, mA
  • Analogue process value output 0/4 ... 20 mA
  • Second setpoint
  • Alarm outputs with 7 different functions
  • Easy to operate
   

R1300
The Universal Controller - Flexible - Compact - Powerful
Manual R1300

Format: 96x96 mm (1/4 DIN)
Installation depth: 122 mm

  • 2-point-controller: (heating or cooling)
  • 3-point-controller: (heating-off-cooling)
  • 3-point-step-controller (for motorvalve application)
  • Continuous-output-controller
    Falling or rising output characteristic
  • Autotune function
  • Relay or bistable voltage output to control solid state relays (SSR)
  • Continuous outputs for both: heating and cooling
  • Sensor: RTD, Thermocouple, 0/4...20mADC,0...10VDC

  • Process-value-offset correction
  • Analogue process value output 0 ... 10 V DC, 0/4 ... 20 mA
  • Analogue setpoint input 0 ... 10 V DC, 0/4 ... 20 mA
  • Second setpoint
  • Programmable setpoint ramp function
    for time controlled rising or falling of the setpoint
  • Alarm outputs with 7 different functions
  • Automatically switching to actuator function
    (in event of sensor break the controller automatically maintains the last valid output ratio as the actuating signal)
  • Softstart function for slow baking out of high performance cartridge heaters
  • Ser. interface RS 485 with ELOTECH Standard ASCII - communication protocol

    © ELOTECH - Industrieelektronik GmbH - Hilden - Last update : 17.02.2009 - Imprint