Mehrzonenregler mit LCD-Display

 


Multizone ( multiloop )
Temperature Controllers

- small space requirement
- low wiring - costs
- heater current monitoring
- softstart function
- fieldbus interface
- best price


Basic functions:
Programmable controller function:
2 point - controller: (heating-off or cooling-off function)
3 point - controller: (heating-off-cooling function)
Programmable output characteristic:
PD / I ( modified PID-algorithm)
P,I,D - Parameter with autotune function
Controller output (actuator):
Relay (on/off)
or
bistable voltage output 0/18VDC, 10mA
to drive external solid state relays ( SSRs )
Individually programmable for each zone:
Sensor input: RTD, TC
Process-value-offset correction
Setpoint ramp function
Second setpoint (standby setpoint)
Automatic output control in case of sensor break:
In the event of sensor break the controller automatically
maintains the last valid output ratio as the actuating
output signal.
Softstart function:
When the softstart-function is active, the output ratio of the controller is limited to a preselected ratio, in order to achieve a slow baking out of high performance heat cartridges.

Options:
Serial interfaces Fieldbus interfaces
Analog inputs 0...10VDC Heater current monitoring
Customized versions with special hardware
and software functions (OEM-versions)
Specific display- and keyboard layout


R 2400

4 / 6 / 8 controller zones

Format: 96 x 96 mm
Depth: 122 mm
Option: heater current monitoring (3 phase)

  • Operation in english language (standard)
  • 2 - point / 3 - point controller function
  • Autotune function
  • Sensor inputs: Pt 100 (RTD) or different thermocouples
  • 2 Alarm contacts (collector contacts)
    with 7 programmable alarm functions
  • Easy to operate
  • Option serial interfaces:
    - RS 485, RS 232-C, TTY
  • Option fieldbus:
    -
    CANopen
    - Profibus DP

Mehr Infos gibts hier



R 2500

4 / 10 / 12 / 16 controller zones

Format: 192x 96 mm
Depth: 122 mm
Option: heater current monitoring (3 phase)

  • Operation in english language (standard)
  • 2 - point / 3 - point controller function
  • Autotune function
  • Sensor inputs: Pt 100 (RTD) or different thermocouples
  • 2 Alarm contacts (collector contacts)
    with 7 programmable alarm functions
  • Easy to operate
  • Option serial interfaces:
    - RS 485, RS 232-C, TTY
  • Option fieldbus:
    -
    CANopen
    - Profibus DP


manual

35mm DIN - rail mounting Option)


R2000-B

2 controller zones
Format: 96 x 96 mm
Depth: 67 mm

  • 2 - point / 3 - point controller functions in one version
  • Autotune function
  • Sensor inputs: Pt 100 (RTD) or different thermocouples
  • 2 Alarm contacts (collector contacts)
    with 7 programmable alarm functions
  • Supply voltage: 24V DC
  • Easy to operate

 

  • Option serial interfaces:
    - RS 485, RS 232-C, TTY
  • Option fieldbus:
    -
    CANopen
    - Profibus DP
  • Option 35mm DIN - rail mounting


R 2000N
( low cost )
4 controller zones

Format: 96 x 96 mm
Depth: 122 mm

Option: heater current monitoring (1 phase)

R 2000

4 / 6 / 8 / 10 controller zones

Format: 96 x 96 mm
Depth: 122 mm
Option: heater current monitoring (3 phase)

  • 2 - point / 3 - point controller function
  • Autotune function
  • Sensor inputs: Pt 100 (RTD) or different thermocouples
  • 2 Alarm contacts (collector contacts)
    with 7 programmable alarm functions
  • Easy to operate
  • Option serial interfaces:
    - RS 485, RS 232-C, TTY
  • Option fieldbus:
    -
    CANopen
    - Profibus DP

 

manual


R 2100

4 / 6 / 8 / 10 / 12 / 16 controller zones

Format: 192 x 96 mm
Depth: 122 mm
Option: heater current monitoring (3 phase)

  • 2 - point / 3 - point controller function
  • Autotune function
  • Sensor inputs: Pt 100 (RTD) or different thermocouples
  • 2 Alarm contacts (collector contacts)
    with 7 programmable alarm functions
  • Easy to operate
  • Option serial interfaces:
    - RS 485, RS 232-C, TTY
  • Option fieldbus:
    -
    CANopen
    - Profibus DP

 

manual


R 2200

4 / 6 / 8 / 10 / 16 controller zones

Format: 125 x 105 x 125mm (B x H x D)
35mm DIN - rail mounting
Option: heater current monitoring (3 phase)

  • 2 - point / 3 - point controller function
  • Autotune function
  • Sensor inputs: Pt 100 (RTD) or different thermocouples
  • 2 Alarm contacts (collector contacts)
    with 7 programmable alarm functions
  • Operation via interface up to 256 zones
  • Standard:
    - RS485 serial interface
  • Option:
    -
    RS232-C
    - TTY

    - CANopen
    - Profibus DP
  • Operation with computer-systems


Current transformer
M2000


Heater current monitoring:
1 Phase current transformer M2000 to operate with:
- R2400
- R2500
- R2000N
- R2000
- R2100
- R2200


For each phase only one current transformer
M2000 is necessary.

Monitoring:
  • Heater current (detects current reduction)
  • Heater current failure (open circuit)
  • Load partly missing
  • Circuit partly interrupted
  • SSR with short circuit
  • Technical data:
  • VDE 0414 EN 50178 (VDE0156)
  • Input current 50A
  • Output current 50mA
  • Transformation ratio 1:1000
  • Max. measuring overload. 20%
  • Easy installing
  • 2 x 6,3mm flat connectors

  • Interfaces


    All
    ELOTECH multizone controllers can be equipped with data interfaces:

    RS 232, RS485, TTY
    Communication protocol:
    ELOTECH - standard ASCII - format
    CANopen
    Device Profile CiA DS-404
    Profibus DP - EN 50170


    Free Software - Tool

    ELOVISION 2000
    The configuration software for
    ELOTECH multizones controller

    Free Download ( ZIP 5,3MB ): here