Premium multiple zone controller

Product description
The RS7100 represents a new class of PID controllers. The algorithm sets new standards, as do the range of functions, the operating concept and the feel of the controller.
With the cascadable R4010 IO module, you can expand the PID controller from 8 zones to 12, 16, 20, 24, 28 or 32 zones.
The adaptive algorithm enables a new quality of control. Fast control with minimal overshoot characterises the algorithm.
On the 7-inch touch display with high reading quality, you can view graphical curves as well as a detailed overview of all 32 displayed zones.
Driven by a powerful embedded Linux processor, the multifunction controller communicates with the outside world via Ethernet, Profibus, Profinet, RS232/RS485, TTY or OPC UA (from Q3 2021), depending on the equipment variant. If the controller is installed in a network, you can conveniently operate all functions as a mirrored user interface via the Viewer software. Alternatively, ELOTECH offers the possibility of a graphic-based system display with the free ELOVISION Windows software.
The energy-optimised heating represents a new innovative type of compound heating. Until now, when there were several heating sections with different heating capacities, all heaters tried to reach their setpoint as quickly as possible. In the process, some heating systems have been working under full load for a long time, while slower heating sections are still heating up. With the innovative new compound heating function, all control sections automatically adapt to the slowest section, so that all heating systems reach the setpoint at the same time and in a correspondingly more energy-saving way. In addition, it can also be significantly less wear and tear on the controlled system if individual components spend less time idling under "full load".
As a mounting option, ELOTECH offers a panel and rear-mounted version. The display controller unit communicates with the connected IO boards via an internal bus. As all input/output signals are directly connected to the IO board mounted in the control cabinet, you avoid greater mounting effort.
Design | 8-zone controller, optional: up to 32 zones (Q1/2021) 2-point /3-point controller |
---|---|
With monitoring tool for comprehensive process control | |
Self-optimising | Yes |
Inputs | PT100 | TC | NI120 | 0...10V | 0/4...20mA |
Outputs | Relay and 0/24 VDC Continuous 0/4…20mA ; 0…10V Hybrid outputs up to 9KW |
Auxiliary voltage | 24 VDC |
Options | Heater current monitoring Interface, serial RS 232 (Modbus RTU, Elotech Std protocol) Interface, serial RS 485 (Modbus RTU, Elotech Std protocol) Interface, serial TTY (Modbus RTU, Elotech Std protocol) Profibus DP interface Optional: OPC UA |
Custom versions to customer preferences | |
Format (WxHxD) |
Individual control solution needed?
We produce cost-effective individually adapted control solutions. Tell us what you need to do - we will find the solution.